Vibration Test
The vibration test was performed in accordance with the test method ISTA Procedure 1A using Lansmont Vibration Tester.
Package was subjected to an increase vibration frequency until the package-product began to momentarily leave the surface of the platform and a metal shim was able to move intermittently between bottom face (face 3) of the package-product and then surface of the platform (vibration table). This frequency was then used to run the fixed displacement vibration test for the duration in accordance with the calculation method as below:
Test Duration in Minutes =
14,200 Vibratory Impacts
Cycles Per second (Hz) x 60
Drop Test
Drop test was performed in accordance with the test method specified in the ISTA Procedure 1A. The drop test was done on the package after it has been subjected to vibration test as described in section 4.1. The drop test was done using Lansmont Drop Tester.